🛰️ Daily AI Frontier
‹ back to 2026-10-24

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

Research Medical/Healthcare AI

Ranking

Overall 84
Content 95
Popularity 59

Observed public metrics from 1 member.

Representative image for A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

Merged summary

TL;DR - RetinaGroundBench evaluates whether multimodal models can localize biomarkers in retinal OCT scans, revealing a large gap between identifying pathology and grounding it visually. An OCT-specific 8B model improves grounding substantially, but performance remains limited.

  • The benchmark contains 815 ophthalmologist-annotated B-scans, 4,537 bounding boxes, 13 biomarkers, and 8 diseases.
  • AggIoU evaluates fragmented predictions by measuring the union of overlapping predicted boxes against annotated regions.
  • Among 27 open-source models, the best general-purpose model reached only 23.7% macro F1 for grounding, despite up to 73% balanced accuracy on biomarker-presence questions.
  • RetGrounder achieved 33.9% grounding F1, a 43% relative improvement over the best general-purpose model.

Sources (1)

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

arXiv cs.CV Ronald Fecso, José Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel, Laetita Hinterhuber, Virginia Mares, Andreas Pollreisz, Hrvoje Bogunović 2026-10-22 arXiv:2610.31205
Public signals Hugging Face upvotes 0 · Semantic Scholar citations 1 · Semantic Scholar influential citations 0
Providers: Hugging Face · Upvotes 0 OpenAlex · N/A Publisher · N/A Semantic Scholar · Citations 1 · Influential citations 0 X · N/A Fetched 2026-11-23 15:33:17.017367 UTC

TL;DR - RetinaGroundBench evaluates whether multimodal models can localize biomarkers in retinal OCT scans, revealing a large gap between identifying pathology and grounding it visually. An OCT-specific 8B model improves grounding substantially, but performance remains limited.

  • The benchmark contains 815 ophthalmologist-annotated B-scans, 4,537 bounding boxes, 13 biomarkers, and 8 diseases.
  • AggIoU evaluates fragmented predictions by measuring the union of overlapping predicted boxes against annotated regions.
  • Among 27 open-source models, the best general-purpose model reached only 23.7% macro F1 for grounding, despite up to 73% balanced accuracy on biomarker-presence questions.
  • RetGrounder achieved 33.9% grounding F1, a 43% relative improvement over the best general-purpose model.
item →