ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health
TL;DR - ECG-SDI uses single-lead ECG data to continuously estimate sleep depth, revealing variation hidden by conventional sleep stages. It could enable scalable at-home sleep phenotyping and monitoring of CPAP response.
- Trained on 12,392 overnight polysomnography recordings, the two-stage model achieved sleep-depth correlations of 0.828 internally and 0.848 externally, excluding REM.
- REM classification AUROC reached 0.954 internally and 0.977 in the external Cleveland Family Study.
- A disturbed sleep phenotype was associated with poorer subjective sleep and higher all-cause mortality (adjusted hazard ratio 1.20).
- Among 507 participants with paired recordings, CPAP increased normalized sleep-depth area by 6.1% and reduced shallow-sleep burden by 16.0%.